No, do not close the actuator before inserting FPC in the case of FH series back flip type connectors.Closing the actuator before inserting FPC may narrow the gap between the c...
No. Because the maximum operating temperature is 85°C, DF37 series is not recommended in the equipment for automotive.However, the maximum operating temperature of FX23 serie...
Please mount the connector with actuator standing(open).
When the FPC is not inserted and the actuator is down(close) ,
the springiness of the contacts will deteriorate.
The lock structure and series name are as follows.FH12 is front flip and vertical flip.FH19C,FH26W,FH28,FH33(J),FH36/W,FH41,FH49,FH50,FH52,FH55M,FH62,FH63S,FH65,FH75,TF06L,TF31...
Insert Interposer by pressing on Installation Cap, then remove Installation Cap.For more information, see the IT3 design note.
IT3 design guideline
https://www.hirose.com/ja...
DF12 * series(Discontinued) and DF12N * series are compatible both in mating and PCB footprints. (* is a symbol representing the design differences , and blank, A, B, C etc. are...
The cable side crimp socket is;
Pin header Cable side socket /RemarksDF63M-2P-7.92DS(A) DF63-3S-3.96C /Insert crimp contacts into No.1 and No.3 cavities
DF63(R)-3P-7....
The Company site may obtain some information using cookies.
In cases where the application will demand a high level of reliability, such as automotive, please contact a company representative for further information.